Digital Integrating Flow rate Meter
MODEL:419A
● Compact 48 x 48 DIN Size
● Dual Display of flow rate and totalizer
● Pulse output for total and 2 x preset output
● Analog input 419A
Model Designation
| 419A | |
|||
1 |
2 |
3 |
4 |
| 1. Measuring input | 2. Power supply voltage | ||||||||||||||||||||||||||||||||||||||||
|
|
| 3. Power source for sensor | ||||||||||||||||||||||||||||||
4. Analog output, RS-485 |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
Basic Specifications
| Flow rate measurement | |
| Flow indication | 0~9999: Red LED,
Character 8mm High, with
zero-suppress function. Programmable Decimal point Over-range indication |
| Display blank | Changeover to be put on or off. |
| Scaling | Full scale and Offset, Programmable 0 - 9999 |
| Resolution | 1/9999 |
| Display cycle | Selectable from the front key. 100ms, 400ms, 1s, 2s, 5s |
| Moving averaging | Selectable from the front key. 1, 2, 3, 4, 8, 16-time |
| Accuracy | ±0.2% of SPAN at23oC±5℃ 45~75%RH |
| Temperature drift | ±200ppm/℃ |
| Input method | Single ended, floating |
| A/D conversio | V-F conversion method |
| Flow totalize
measurement |
|
| Flow indication | 0~99999: Green LED,
Character 8mm High, with
zero-suppress function. 5 or 10 significant digit: Over-range indication: Display blank: Changeover to be put on or off. |
| Integration constant | Values integrated in 1 hour at 100% input, programmable from the front key. |
| Primary integrated value | from 0 to 99999, programmable from the front key |
| Accuracy | ±(0.2%+1digit) of
rated value Rated value: theoretical value when input 100% continuously. |
| Display cycle | approx. 100ms |
| Common
Specifications |
|
| Cut off | 0 to 10%: Programmable from the front key. |
| Latch / Pose input | Latch: hold display of instantaneous and integrating flow rate, and data output (except of Simultaneous pulse output). Accumulated integrated count will be operated. Pose: hold display of instantaneous and integrating flow rate, and data output. Accumulated integrated count will be temporarily stopped. Non-voltage contact or open collector (NPN) DC5V 10mA |
| Reset | reset to 0 or primary setting value |
| Backup | An EEPROM retains the data of accumulated total flow when the power is interrupted. Keep 10 years. |
| Output | relay contact: AC/DC 150V 80mA |
| Noise filter | 50dB at normal mode 110dB at common mode 1000V against the power line noises |
| Withstanding Voltage | Input terminals -
Case : AC1500V each for 1 min. Power supply terminals - Case : AC1500V each for 1 min. Power supply terminals - Input and Output terminals : AC1500V each for 1min. Input terminals - Output terminals : AC500V each for 1 min. |
| Insulation Resistance | DC500V 100MΩor more. |
| Power Supply | AC 100 to 240V (50/60HZ), DC12V±10%, DC24V±10% |
| Allowable power | AC 90 to 250V (50/60Hz), DC10.8 to 13.2V, DC21.6 to 26.4V |
| Power Consumption | Approx. 7.5VA at AC100V, 10VA at AC200V, 400mA at DC12V, 250mA at DC24V. |
| Operating Temperature | 0 to 50℃ |
| Storage Temperature | -20 to 70℃ |
| Weight | Approx. 160g |